CLIMB Noise Tests 2010JUN

From Monnier Group Research Wiki
Revision as of 00:25, 11 June 2010 by 192.153.157.221 (talk) (New page: on UT 2010Jun10, we took some test data on a K=XX mag source using 500Hz SYNC and 500Hz NORM on CLIMB to compare the noise properties. We also put in the H-band filter to help estimate ...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search


on UT 2010Jun10, we took some test data on a K=XX mag source using 500Hz SYNC and 500Hz NORM on CLIMB to compare the noise properties. We also put in the H-band filter to help estimate the observed K band background counts. Lastly, we compared this to the NIRO performance, both noise and throughput from 2009 June.


Conclusions:

1. CLIMB has 50% less throughput than NIRO. One can see the Telescope -> Pixel Map does not follow the expected flux distribution, strongly suggesting there is some misalignment presently.

2. NORM mode is worse than SYNC mode. compare also 250Hz to 500Hz NORM.




Details