2011-06-18 (UT) ========== Program: CL4 (YSOs, PI: Kraus et al.) Observers: Fabien, Gail, FLUOR team B1 B2 B3 ---------- E1 W1 W2 (W1=REF) (S1S2E1E2W1W2: 4-5-1-3-1-5) CLIMB on beam 1,2,3 LT - 20:30 *** E1W1W2, W1=ref. weather cloudy till midnight, seeing = 4-6 cm, very bad piston NIRO align on delta sco 21:00 360 / -2720 HD140990 (seeing is bad) 260/-2420 counts: 15 / 15 / 15 (not great but last time saturated at slower speeds) V: 0.56/ 0.66 / 0.46 21:12 220 / -2400 HD142666 not enough counts anyway lost tip/tilt and needed to change NSUM to 5 and niro crash redoing calibrator 500Hz/NONDEST/FULL HD140990 21:40 128 / -2210 counts: 15 / 20 / 15 V: 0.49 / 0.54 / 0.38 122/-2197 could not find fringes on target, giving up CLOUDS ! Fluor target (HR6623/HD161797) 23:00 cal HD 159925 -430/-1434 750/DEST counts: 30/40/35 V: 0.32 / 0.36 / 0.36 23:07 -300 / -1400 23:16 -200/-1380 23:19 -150 / -1300 HD161797 counts: 400 / 400 / 400 V: 0.04/ 0.21 / 0.09 23:28 -260 / -1370 HD 159925 counts: 90 / 120 / 100 V: 0.27 / 0.35 / 0.22 23:32 -350/-1370 23:39 HD161797 -80/-1240 counts: 500-1000 all V: 0.03 / 0.26 / 0.09 23:46 -75 / -1210 HD 159925 counts: 100 / 150 / 120 V: 0.27 / 0.33 / 0.22 23:59 -120/ -1390 MWC 614 CLOUDS ! can't lock tip/tilt for more than a minute MWC 361 0:50 NIRO ALIGN on HD 197950 recording at 750/DEST ??? / -2640 1:20 -1720 / ??? 1:53 -1690/-2280 recording at 750/DEST (very breezy ! high piston) counts: 25 / 25/ 25 V: 0.48 /0.41 / 0.22 CLOUDS Very bad piston and r0 for a while......... NIRO ALIGN on HD 197950 HD 197950 3:02 -1830 / -2200 counts: 45 / 50 / 45 V: 0.30 / 0.35 / 0.21 3:08 -1680 / -2180 MWC 361 3:21 -1820 / -2290 (took 100 scans before finding all fringes, then lost them at the end...) counts: 85 / 90 / 75 V: 0.11/ 0.21/0.11 flux not stable due to clouds 3:35 -1640 / -2190 HD 197950 counts: 60 / 65 / 55 V: 0.33 / 0.34 / 0.19 3:39 -1730 / -2170 MWC 361 3:51 -1720 / -2310 counts: 100 / 120 / 95 V: 0.07 / 0.21 / 0.06 stopped after a while, only ~30 (use only first shutter sequence for safety ?) 4:04 -1840 / -2230 HD 197950 // add to scrap this when lost tip/tilt during shutter sequence 4:17 -1910/-2260 HD 197950 counts: 70 / 85 / 65 V: 0.48 / 0.52 / 0.41 4:30 MWC 361 (only decent quality target data so far) -1860 / -2320 counts: 120 / 135/ 102 V: 0.07 / 0.25 / 0.08 4:35 -1970 / -2320 4:40 -2060 / -2440 HD198236 counts: 105 / 120 / 95 V: 0.34 / 0.34 / 0.26 5:02 MWC 361 (short one to get a calibrator) counts: 100/ 120 / 115 V: 0.07 / 0.22 / 0.10 -2031/-2308 5:17 HD 197950 counts: 80 / 80 /80 V: 0.31 / 0.38 / 0.27 ---- summary of observations: mu Her 2 brackets (FLUOR target) MWC 361 4 brackets (though only 1.5 worth of decent quality data...)