2011-06-17 (UT) ========== Program: CL4 (YSOs, PI: Kraus et al.) Observers: Fabien Baron, PJ Goldfinger, FLUOR team B1 B2 B3 ---------- E1 W1 W2 (W1=REF) (S1S2E1E2W1W2: 4-5-1-3-1-5) CLIMB on beam 1,2,3 LT - 20:30 *** E1W1W2, W1=ref. weather clear, seeing = 4 cm 20:55 NIRO align on HD141247 scanning for fringes at 250Hz 21:05 -230/-1950 seeing too bad to continue on this target (as the cal does not have stable fringes) MWc 863 21:26 NIRO align on HD150698 198/-3200 21:40 300/-3100 recording at 500/NONDEST counts: 40 / 40 / 25 V: 0.45 / 0.40 / 0.26 this set was hard to get because of seeing = 4 cm 21:44 200 / -3100 MWC 863 no success waiting for MWC 275 22:20 NIRO align on HD 162255 scanning for offsets ???/-3100 hd 163955 22:40 340 / -3040 500Hz/NONDEST/HALF counts: 50 / 50 / 50 when all fringes are there... V: 0.42 / 0.32 / 0.41 (not so great despite NIRO align) 22:45 270/-2990 redoing in 500Hz/DEST/FULL as saturated ... redoing NIRO align too 23:00 recodring at 500/DEST 230 / -2850 counts: 40 / 30 / 20 V: 0.50 / 0.39 / 0.33 23:05 500/ -2680 23:10 45 / -2880 MWC 275 humidity spike + r0 = 2 cm Seeing better now 0:45 trying v1295 Aql NIRO align on HD 188385 0:50 scanning -470 / -1700 recording at 750/NONDEST/HALF counts: 30 / 30 / 25 V: 0.64 / 0.63 / 0.68 0:55 -520/-1660 1:08 -456 / -1677 v1295 Aql (decent set) counts: 40 / 35/ 30 V: 0.15 / 0.25 / 0.12 1:13 -460 / -1660 1:20 HD 189509 -490/-1560 counts: 30 / 35/ 30 V: 0.65 / 0.60 / 0.71 1:24 -480 / -1530 niro server crash but got it back v1295 Aql (at first not much signal, then got better) 1:34 -485/-1488 counts: 30 / 30 / 30 V: 0.19 / 0.23 /0.11 1:39 -520 / -1521 1:48 -593/-1450 HD 188385 counts:: 30 / 30 / 25 V: 0.65/ 0.59 / 0.62 1:53 v1295 Aql counts: 50 / 45/ 30 V: 0.17 / 0.22 / 0.12 2:01 -580 / -1450 2:09 HD 189509 counts: 35 /30 / 20 V: 0.59 / 0.64 / 0.58 2:13 -612 / -1400 2:24 -650 / -1409 v1295 Aql (less frequent fringes, r0 worse) counts: 25 / 30 / 20 V: 0.17 / 0.22 / 0.13 2:29 -680 / -1400 2:35 HD 188385 counts: 25 / 30 / 18 V: 0.57 / 0.62 / 0.63 -730 / -1390 2:44 v1295 Aql counts: 40 / 40 / 20 V: 0.19 / 0.22 / 0.14 2:49 -690/ -1350 2:52 -700 / -1350 2:57 HD 189509 counts: 25 / 25 / 15 V: 0.53 / 0.72 / 0.59 3:01 -690 / -1340 ------------- MWC 1080 NIRO align on HD 216425 cal HD 216425 3:40 -1630 / -2260 counts: 70 / 70 / 70 (but did not saturate) V: 0.46 / 0.53 / 0.52 3:58 MWC 1080 -1660/-2230 counts: 60 / 60 / 50 V : 0.08 / 0.26 / 0.06 only 50 scans with all fringes + I forgot to turn on servo at first... 4:11 -1630 /-2200, end sequence HD 216425 4:14 counts: 70 / 70 / 70 V: 0.45/ 0.49 / 0.46 Failed to get the next brackets as the tip/tilt could not get the star anymore despite trying all sorts of things... ---- summary of observations: v1295 Aql 5 brackets MWC 1080 1 bracket