2011-06-14 (UT) ========== Program: CL4 (YSOs, PI: Kraus et al.) Observers: Fabien Baron, PJ Goldfinger, FLUOR team B1 B2 B3 ---------- E1 W1 W2 (W1=REF) (S1S2E1E2W1W2: 4-5-1-3-1-5) CLIMB on beam 1,2,3 LT - 20:40 *** E1W1W2, W1=ref. start: weather clear, humidity <40% r0 = 3-5 cm at first, then rose up to 8-9 cm much better piston today scan length LONG HD142666 check star delta sco 21:10 200/-2845 21:40 HD140990 -20/-2290 500/NONDEST/FULL counts: 25 / 40 / 15 V: 0.42/0.58/0.47 21:45 -70/-2310 21:51 -15/-2300 HD 142666 22:04 needed to use 500/NONDEST/HALF APERTURE -50/-2335 22:07 -5/-2344 counts: 25 / 40 / 20 V: 0.18 / 0.44 / 0.18 switch to HD140990 22:15 -113 / ??? recording at 500/NONDEST/HALF APERTURE counts: 20 / 30 / 10 V: 0.50 / 0.71 / 0.54 ---------- trying MWC275 (back to FULL APERTURE) NIRO align 22:35 HD 163296 could not find fringes by scanning new NIRO align 23:19 HD 162255 130/-2600 recording at 500Hz/DEST counts: 35 / 40 / 25 V: 0.49 / 0.59 / 0.40 23:25 130/ -2570 switching to MWC275 23:35 70/-2500 recording at 500Hz/DEST counts: 80 / 100 / 50 V: 0.11 / 0.15 / 0.10 23:41 60 / -2470 23:47 24/-2500 HD 162255 recording at 500Hz/DEST 23:55 5/-2400 counts: 40 / 50 / 25 V: 0.49 / 0.67 / 0.55 0:00 -20 / -2400 0:08 MWC275 recording at 500Hz/DEST counts: 95 / 120 / 70 V: 0.11 / 0.15 / 0.09 -73/-2300 0:21 HD 170680 20 / -2180 recording at 500Hz/DEST counts: 50 / 65 / 40 V: 0.50 / 0.58 / 0.36 0:30 5 / -2160 ------------- trying v1295 Aql 0:40 HD 188385 NIRO align 0:46 ??? /-1800 recording at 500Hz/DEST the beginning of the file has only W1W2, as we were waiting for delay on the other baselines then we have all 3 (nice) fringes counts: 30 / 30 / 30 V: 0.66 / 0.67 / 0.60 0:55 -130 / -1700 switching to v1295 Aql recording at 500Hz/DEST 1:05 -140/-1730 counts: 45 / 40 / 35 V: 0.15 / 0.26 / 0.12 lost tip/tilt on E1 at some point, shutter sequence should not be affected (but will need to compare with first shutter sequence which was definitively not affected) 1:10 -150 / -1690 -190 / -1700 back to HD 188385 1:25 recording at 500Hz/DEST -240/-1540 counts: 35 / 35/ 25 V: 0.68 / 0.64 / 0.67 1:35 v1295 Aql recording at 500Hz/DEST -240/ -1520 counts: 35 /35 / 25 V: 0.15 / 0.22 / 0.12 1:42 -290 / -1530 HD 189509 1:54 -280 / -1400 recording at 500Hz/DEST counts: 25 / 25/ 20 V: 0.63 / 0.58 / 0.58 2:00 -300 / -1380 2:09 v1295 Aql -410 / -1400 recording at 500Hz/DEST counts: 30 / 25 / 20 V: 0.18 / 0.21 / 0.16 fringes other than W1W2 at the limit of detection only a few frames (~ 20) where they are all present 2:28 HD 188385 -380 / -1290 counts: 25 / 25/ 10 V: 0.58 / 0.53 / 0.53 ---------------- switching to MWC 340 HD 195988 , NSUM = 25 2:45 NIRO ALIGN recording at 250 Hz/ DEST (shortened the sequence at 140 samples to test MWC340 early) -600 / -1470 counts: 45 / 55/ 40 V: 0.46 / 0.40 / 0.34 2:56 -540 / -1490 MWC 340 3:09 -575/ -1480 counts: 40 / 60 / 50 V: 0.11 / 0.23 / 0.19 3:18 -600 / -1500 HD 194708 3:29 -580 / -1530 counts: 40 / 55 / 45 V: 0.50 / 0.34 / 0.38 3:35 -540 / -1490 MWC 340 3:51 star finally acquired / but tip tilt issues 4:15 reacquired MWC340 tip/tilt crash ------------- MWC 1080 cal HD 216425 4:38 -1440/-2050 recording at 500 Hz/ DEST counts: 66 / 80 / 50 V: 0.39 / 0.44 / 0.31 4:45 -1475/-2052 MWC 1080 counts: 60/30/20 v: ??/0.24/?? 2T ONLY, W1W2, though we scanned around for fringes lost B1 (E1) and B2 before the end shutter sequence Use only the starting shutter sequence anyway ---- summary of observations: HD142666 1 bracket MWC 275 2 brackets v1295 Aql 3 brackets MWC 340 1 bracket (tip/tilt crash prevented a second one) MWC1080 1 bracket, 2T only